HVAC glossary: the terms on your quote, explained.
AFUE, SEER2, MERV, Manual J, static pressure. Contractors use these words as though everybody knows them. Here is what each one means and, more usefully, why it should change what you decide.
- Carrier Factory Authorized Dealer
- NATE-certified technicians
- No jargon on our quotes either
- Locally-owned since 2008
Section one
The numbers: efficiency and sizing
These are the figures that appear on a quote and in a manufacturer's brochure. Two of them — tonnage and Manual J — matter more than all the others put together.
| Term | What it means | Why it matters to you |
|---|---|---|
| AFUE | Annual Fuel Utilization Efficiency. The percentage of the fuel a furnace or boiler turns into heat in your house over a season, rather than up the flue. | An 80% furnace sends a fifth of what you buy outside. A 95%+ condensing furnace sends about a twentieth. On a cold-winter gas bill that gap compounds fast. |
| SEER2 | Seasonal Energy Efficiency Ratio, version 2. Cooling output over a season divided by the electricity used. SEER2 replaced the old SEER rating in 2023 under a tougher test method. | Higher is cheaper to run. Do not compare a SEER2 number against an old SEER number from a brochure — the tests are different and SEER2 figures read lower for the same machine. |
| EER2 | The same idea as SEER2 but measured at one hot design condition rather than averaged across a season. | It tells you how the unit behaves on the worst afternoon of the year, which is the day you will actually be judging it. |
| HSPF2 | Heating Seasonal Performance Factor, version 2. The heat-pump equivalent of SEER2, covering heating rather than cooling. | The number to look at if you are considering a heat pump in Wisconsin. It is the one that decides your winter electric bill. |
| BTU | British Thermal Unit. A unit of heat. Equipment is rated in BTU per hour — how much heat it can move in an hour. | It is the common currency for comparing any two systems, whatever fuel they burn. |
| Ton / tonnage | A cooling capacity unit. One ton equals 12,000 BTU per hour. A three-ton air conditioner moves 36,000 BTU per hour. | Nothing to do with weight. It is the number most often got wrong, because installers copy the tonnage of the old unit instead of calculating what the house needs. |
| Manual J | The industry-standard heating and cooling load calculation. It works out how much heat your specific house loses and gains, using its size, insulation, windows, orientation and air-tightness. | This is the difference between a system sized for your house and one sized for the last guy's guess. Ask any contractor whether they are doing one. |
| MERV | Minimum Efficiency Reporting Value. A 1 to 16 scale of how much of what passes through a filter the filter actually catches. | Most homes want MERV 8 to 13. Higher is not automatically better — a dense filter on a system not designed for it starves the blower and costs you airflow. |
| Static pressure | The resistance the duct system puts up against the air the blower is trying to push, measured in inches of water column. | Most residential equipment is designed around roughly 0.5 in. w.c. Plenty of real houses run far above it, which is why a new furnace on old ducts can be noisy, uneven and hard on itself. |
If you only take one thing from this section: an oversized system is not a safe bet. It short cycles, dehumidifies poorly, wears itself out faster and costs more to buy. Bigger is not a margin of safety.
Section two
The parts: what the technician is pointing at
| Term | What it is | Why it matters to you |
|---|---|---|
| Heat exchanger | The metal chamber inside a furnace where combustion happens. It transfers heat into your air while keeping the exhaust gases separate from it. | If it cracks, combustion gases including carbon monoxide can reach the air you breathe. A cracked heat exchanger means the furnace is shut off and replaced. There is no repair. |
| Condenser | The outdoor unit. It contains the compressor and a coil, and its job is to dump the heat collected from inside your house into the outside air. | Keep two feet clear around it and do not build a deck over it. Starved of airflow it works harder, runs hotter and fails sooner. |
| Evaporator coil | The indoor coil, usually sitting on top of the furnace. Refrigerant absorbs heat from your household air as it passes over it. | It is also where humidity is removed, as water condenses on the cold fins and drains away. A dirty or iced coil is one of the most common causes of poor cooling. |
| Refrigerant | The fluid that carries heat between the indoor and outdoor coils, changing between liquid and gas as it goes. | A system does not consume refrigerant. If yours is low, it has a leak, and topping it up without finding the leak is throwing money at a symptom. |
| R-410A | The refrigerant used in most residential systems installed from the early 2000s onwards. It replaced R-22. | It is being phased down for new equipment on environmental grounds. Existing R-410A systems keep running and can still be serviced, but the refrigerant will get dearer over time. |
| R-454B | A lower-global-warming-potential refrigerant now used in new residential equipment, including Carrier's. It is classed A2L, meaning mildly flammable, which brings new handling and installation requirements. | If you are buying a new system it will most likely be on R-454B. It is not interchangeable with R-410A, so you cannot mix old and new components across the two. |
| HRV | Heat Recovery Ventilator. It exhausts stale indoor air and brings in fresh outdoor air, transferring heat between the two streams so you are not throwing your heating away. | The usual choice for a tight house in a cold, heating-dominated climate. It moves heat but not moisture. |
| ERV | Energy Recovery Ventilator. The same as an HRV, but it transfers moisture as well as heat between the incoming and outgoing air. | Preferred where summer humidity is a problem as well as winter cold, which on the Sheboygan lakeshore describes most houses. |
| Zoning | Splitting one system into separately controlled areas, using motorised dampers in the ducts and a thermostat per zone. | The right answer for a house where upstairs and downstairs never agree. It only works on a duct system that can take it, which has to be checked first. |
Section three
How equipment runs
These are the words that separate two quotes that look similar on price. They describe how the system behaves once it is in your house.
| Term | What it means | Why it matters to you |
|---|---|---|
| Single-stage | The equipment is either fully on or fully off. One speed, full output, every time it runs. | Cheapest to buy. Bigger temperature swings, more noise at start-up, and the least effective at controlling humidity. |
| Two-stage | Two output levels — typically around two-thirds capacity and full capacity. It runs on low most of the time and steps up only when it has to. | Longer, gentler run times at low stage, which evens out temperatures and removes more moisture. A sensible middle option for most houses. |
| Modulating | The burner adjusts its output continuously across a wide range rather than in fixed steps, matching what the house is losing at that moment. | The most even heat you can buy and the quietest. It costs more up front and the payback depends on how much of the winter you spend in the middle of the range. |
| Variable speed | Describes the blower motor rather than the burner. The fan ramps its speed up and down instead of switching between off and flat out. | Quieter, better filtration because air moves more of the time, and noticeably less draft. Often confused with modulating — they are different things and a system can have one without the other. |
| Dual fuel | A heat pump paired with a gas or LP furnace. Controls switch between them automatically based on the outdoor temperature. | The heat pump covers the mild majority of the season cheaply; the furnace takes the deep cold. On LP properties this is very often the best-value configuration available. |
| Short cycling | The system starts, runs for a few minutes, shuts off, and starts again soon after. | A symptom, not a fault in itself. The causes are usually a blocked filter, a restricted duct system, a failing sensor, or a system oversized for the house. Every one of them is worth chasing down — short cycling is hard on equipment. |
| Cold-climate heat pump | A heat pump engineered to keep producing useful heat well below freezing, rather than giving up around 35°F as older units did. | Makes heat pumps viable in Wisconsin. Output still falls as it gets colder, so sizing and a plan for the coldest nights still matter. |
Where these terms show up
Take a term to the page it belongs to
AFUE, heat exchanger, two-stage
The furnace terms. If you are reading a heating quote, these are the three that change what you get.
Heating & furnaces
SEER2, tonnage, evaporator coil
The cooling terms. Tonnage is the one most often got wrong, and it is the one you should ask about first.
Air conditioning
HSPF2, dual fuel, cold-climate
The heat pump terms. These decide whether a heat pump makes financial sense on your house or not.
Heat pumps
MERV, ERV, HRV
The air quality terms. Filtration, ventilation and humidity are three separate problems and they need three different answers.
Indoor air qualityStraight answers
The questions behind the jargon
What is a good AFUE rating for a furnace?
In a Wisconsin climate, a condensing furnace at 95% AFUE or above is the sensible default, and 80% only makes sense in specific venting situations. AFUE is the share of the fuel you buy that becomes heat in the house, so an 80% furnace sends roughly a fifth of your gas bill out of the flue while a 95% furnace sends about a twentieth. Over a heating season here that difference is real money. More on furnaces here.
What is the difference between SEER and SEER2?
SEER2 is the current cooling efficiency rating and it replaced SEER in 2023 under a tougher test procedure that accounts for realistic duct resistance. Because the test is harder, the same machine scores a lower number under SEER2 than it did under SEER, so comparing a SEER2 figure against an old SEER figure will mislead you. Compare SEER2 to SEER2 only.
What MERV rating filter should I use?
MERV 8 to 13 suits most homes, and higher is not automatically better. A denser filter catches more but also resists airflow more, and fitting a high-MERV filter to a system that was not designed for it starves the blower, raises static pressure and can cause the very problems you were trying to solve. If you want serious filtration, the right answer is usually a properly sized media cabinet rather than a thicker filter in the existing slot. More on air quality here.
What size furnace or air conditioner do I need?
The only honest answer comes from a Manual J load calculation on your specific house, which accounts for square footage, insulation, windows, orientation and air-tightness. Copying the capacity of the existing unit is the most common shortcut in the trade and it perpetuates whatever mistake was made last time. Oversizing in particular causes short cycling, poor humidity control and shorter equipment life.
What is replacing R-410A refrigerant?
R-454B is the low-global-warming-potential refrigerant now going into new residential equipment, including Carrier's. It is an A2L classed refrigerant, meaning mildly flammable, which brings different handling and installation requirements. Existing R-410A systems keep running and can still be serviced, but the two are not interchangeable and R-410A will become more expensive over time.
What is short cycling and is it serious?
Short cycling is when a system runs for only a few minutes, shuts off, and restarts soon after, and it is worth chasing down. It is a symptom rather than a fault: the usual causes are a clogged filter, a restricted duct system, a failing sensor or limit switch, or equipment oversized for the house. Left alone it wastes energy, leaves the house unevenly heated or cooled, and wears out components that hate frequent starts. Furnace repair here.
What is the difference between an ERV and an HRV?
Both exhaust stale indoor air and bring in fresh outdoor air while recovering energy from the outgoing stream; the difference is that an HRV transfers heat only, while an ERV transfers moisture as well. In a cold, heating-dominated climate an HRV is often enough, but where summer humidity is also a problem — which describes most of the Sheboygan lakeshore — an ERV is usually the better fit.
What is static pressure and why does my contractor measure it?
Static pressure is the resistance your duct system puts up against the air the blower is trying to move, measured in inches of water column. Most residential equipment is designed around roughly 0.5 in. w.c., and plenty of real houses run well above it, especially older ones whose ducts were built for a slow-moving gravity furnace. Installing modern equipment without measuring it produces noise, uneven room temperatures and premature blower failure, which is why we take the reading before we quote.
Got a quote you cannot read?
Bring it to us. We will tell you what the terms on it mean and whether the sizing stacks up, whether or not the quote came from us.