Boiler installation, repair and maintenance in Sheboygan County.

Sheboygan County · Install, repair, service

Boiler installation, repair and maintenance in Sheboygan County.

A lot of shops in this county will not go near a boiler. We will. Cast iron and condensing, combi and conventional, feeding radiators, baseboard or in-floor loops — we install them, service them and repair them, including the ones somebody else put in thirty years ago.

  • We work on boilers
  • NATE-certified technicians
  • Cast iron and condensing
  • Locally-owned since 2008

How we work on boilers

Six things we get right before the boiler goes in

01

We start with the system, not the boiler

The boiler is the easy part. What decides whether the house is comfortable is the heat loss of each room and whether the radiators, baseboard or floor loops you already have can put out that much heat at the water temperature the new boiler wants to run. We work that out before we pick anything.

02

Water temperature decides everything

A condensing boiler only reaches its rated efficiency when the water coming back to it is cool. Big old cast iron radiators sized for 180-degree water will keep the return hot and the boiler will never condense. Outdoor reset, more emitter surface, or both — that is the design work, and skipping it is how people buy a 95% boiler and run it at 85%.

03

Near-boiler piping is where installs go wrong

Pump placement relative to the expansion tank, primary and secondary loops, air elimination, and proper purge points. Get these wrong and you get a boiler that short-cycles, a system full of air, and rooms that never come up. This is the part nobody photographs and the part that matters most.

04

We check incoming line voltage

A modern modulating boiler is a control board with a burner attached. Line voltage in parts of the county runs near the top of the legal ANSI range, and that quietly degrades the electronics. We measure it before we install. Most contractors do not, and then wonder why a five-year-old boiler is on its second board.

05

Zoning gets designed, not bolted on

Zone valves or individual circulators, how many zones the house actually justifies, and whether the boiler can turn down far enough to serve one small zone without short-cycling. Over-zoning a boiler that cannot modulate is a common and expensive mistake.

06

You get a labelled system

Zones tagged, isolation valves marked, the reset curve written down, and a walk-through so you know what to look at when something feels off. Boiler rooms tend to accumulate decades of undocumented decisions. We try not to add to that.

A condensing boiler that runs 180-degree water all winter is just an expensive cast iron boiler. The number on the sticker only happens if the system is designed to run cool.

Choosing the boiler

Cast iron, condensing, or combi?

There is a reason so many 1960s cast iron boilers are still running in this county, and a reason we still install condensing units in most new jobs. They are good at different things.

What to weigh Cast iron conventionalCondensing modulatingCombi
Efficiency you can expect Roughly 80 to 85%, and it does not varyLow to mid 90s — but only if return water stays coolSame as condensing
How it vents Metal flue or an existing chimneyPVC out a sidewall, plus a condensate drainPVC out a sidewall, plus a condensate drain
What it suits Older high-temperature cast iron radiatorsIn-floor loops, panel radiators, or any system run on outdoor resetSmaller homes and tight mechanical spaces
Household hot water Comes from a separate applianceSeparate appliance, or an indirect tank off the boilerProduced on demand by the same unit
Electronics and moving parts Very few. Extremely forgivingBoards, sensors, a modulating gas valve, a condensate trapAll of that, plus a diverter and a flow sensor
Space it takes up Large, heavy, floor standingCompact, often wall hungSmallest footprint of the three
How long they tend to last Thirty years and beyond is commonShorter than cast iron, comfortably longer than a furnaceShorter than cast iron; it works harder year round
Water quality tolerance ForgivingFussy — narrow heat exchanger passages need clean system waterFussy, for the same reason

If your house runs big cast iron radiators on 180-degree water, a condensing boiler is not automatically an upgrade. It becomes one when we can also bring the water temperature down — outdoor reset, more emitter surface, or both. Otherwise you have bought a fragile boiler and kept the old fuel bill.

Straight answers

Boiler questions we get asked

Do you actually work on boilers? A lot of companies around here do not.

Yes — boiler installation, repair and annual service are all things we do, on cast iron and condensing units alike. It is genuinely a differentiator in Sheboygan County, where a lot of heating companies have narrowed down to forced air only. We also work on boilers we did not install, which is most of them.

How much does boiler installation cost?

Boiler installation cost is driven far more by the system than by the appliance: whether the venting has to change from a chimney to sidewall PVC, how much near-boiler piping has to be rebuilt, how many zones there are and whether they need reworking, whether an indirect tank is part of it, and how tight the mechanical space is. A straight like-for-like cast iron swap and a full conversion to a zoned condensing system are very different jobs. We look at it in person and give you a written price with the line items visible.

How long does a boiler last?

Longer than a furnace, usually by a wide margin — cast iron boilers running thirty to forty years are not unusual in this county, and we still service plenty of them. Condensing boilers do not match that; they have more electronics, thinner heat exchanger passages and they are less forgiving of poor system water. They are still long-lived, just not cast-iron long-lived. The trade is efficiency and control against sheer durability.

Should I replace my old cast iron boiler with a condensing one?

Only if we can also get the water temperature down, otherwise you will not see the efficiency you paid for. A condensing boiler earns its rating by pulling heat out of the flue gases until they condense, and that only happens when the water returning to it is cool. If your radiators were sized for 180-degree water and nothing else changes, the boiler runs hot and never condenses. Add outdoor reset, or more emitter surface, and it becomes a genuinely good upgrade. That is the conversation to have before anyone quotes you equipment.

My boiler pressure keeps dropping. Is that serious?

It means water is leaving the system somewhere, and it is worth looking at rather than topping up every few weeks. The usual causes are a waterlogged or failed expansion tank, a relief valve that is weeping, or a small leak in the loop or at a fitting. Repeatedly refilling the system is the thing to avoid — every top-up brings in fresh oxygen and minerals, and that is what corrodes the inside of a heating system.

One part of the house is cold and the rest is fine. Is the boiler failing?

Almost certainly not — if some rooms are warm, the boiler is making heat and the problem is in getting it to that zone. The usual suspects are air trapped in a loop, a stuck zone valve, a failed circulator, or a system that was never balanced. This is why we look at the distribution side and the boiler as one thing. More on the distribution side here.

How often should a boiler be serviced?

Once a year, before the heating season. A boiler service is not the same list as a furnace tune-up: combustion analysis and burner cleaning, yes, but also expansion tank charge, relief valve, low water cutoff, system pressure, circulators and zone valves, and the condition of the system water. Condensing boilers additionally need the condensate trap and the heat exchanger kept clean, and they are less tolerant of being ignored than cast iron ever was.

What is the difference between a boiler and hydronic heating?

The boiler is the appliance that heats the water; hydronic heating is everything that carries that hot water around the house and gives the heat up to the rooms. Radiators, baseboard, in-floor loops, circulators, zone valves and manifolds are the hydronic system. You need both, they fail in different ways, and a boiler in perfect health can still leave you with a cold bedroom. The hydronic side is covered here.

Can I get air conditioning in a house that has a boiler?

Yes, but it will be a separate system, because hot water heat has no ductwork to share. The two normal answers are ductless mini-splits, which need no ducts at all, or a conventional ducted air conditioner if there is a sensible route for ducts. Ductless is what most boiler houses around here end up with. Our cooling page covers both.

Tell us what is in your boiler room.

Make, rough age, how many zones, and what it is doing. If you are not sure, a photo of the boiler and the piping around it tells us most of what we need to know.

Or call us directly

(920) 564-2333

Mon–Fri 7am–3pm. After hours, the same number reaches our on-call technician.